Solenoid Valve Specifications and Dimensions: 2H012-016 Series

$116.45

Electrical Connection: D = DIN (with LED)

Services: Air, Water, Liquid

Features: 2-Way, Normally Closed

Direct Acting

Body: Stainless Steel

Operating Temperature:

FKM Seal: -15 to 120°C

PTFE Seal: -20 to 180°C

Operating Pressure:

0 to 1000PSI

Coil Power: 14W

Response Time: <20msec

Data Sheet:

2H012-016.PDF

Download Drawings

Description

Specifications
Model 2H012-1/8 2H016-1/4
Port Size 1/8″ NPT 1/4″ NPT
Orifice 1.2mm 1.6
Cv 0.05 0.09
Valve Type 2-Way, 2-Position, Body Ported
Action Direct Acting (Poppet)

Fast Response Time: <20msec

De-Energized State Normally Closed (NC)
Body Material
Valve Body:

Armature Assembly:

304 Stainless Steel

Stainless Steel

Seal Material
Standard Option:

Upgrade Options:

Viton (FKM)

PTFE (Teflon)

Operating Temperature
Media with Viton Seal:

Media with PTFE Seal:

5°F to 248°F (-15°C to 120°C)

-4°F to 356°F (-20°C to 180°C)

Operating Pressure 0 PSI to 1000 PSI
Electrical Connection
D:

G:

DIN 43650A

Grommet

Coil Power
AC Coil:

DC Coil:

33VA

12-20W

Voltage Options
12VDC

24VDC

24VAC (50/60Hz)

110/120VAC (50/60Hz)

220/240VAC (50/60Hz)

Voltage Tolerance ±10% of Specified Voltage
Ingress Protection IP65
Insulation Class F Class
Coil Duty 100% ED, Continuous Duty
Installation No Orientation Requirement
Service Liquid, Water, Oil, Air, Gas, Cryogen
Dimensions

2S012-020-A Series Solenoid Valve Dimensions
Model Port A B C D E F
2H012-1/8 1/8″ NPT 80.0 24.5 72.4 34.5 35.6 25.0
2H016-1/4 1/4″ NPT 82.3 28.5 72.4 34.5 35.6 25.0
Dimensions for Reference Use Only: Units in mm

The 2H012-016 valves are direct acting solenoid valves that do not require a minimum operating differential pressure. As shown in the diagram below, when the coil is de-energized (left diagram), the plunger rests on the main orifice and is held in place by the plunger spring force, sealing the valve. When the coil is energized (right diagram), the solenoid lifts the plunger and allows the working medium to flow through the orifice. The working medium and flow direction are indicated in purple in the diagram.

STC’s high performance direct acting plastic body solenoid valves offer reliability, compact and rugged designs, low power consumption, high-speed response, long-life cycle (over 10 million cycles), DIN connections and indicator lights, pre-wired electrical connections, manifold mounting options, and simple installation, maintenance, and control.

 

Operation Diagram

 

Electrical Coil Connections

    • To Connect a DIN Coil:
      • Remove the Philips screw from the plastic housting & unplug from the DIN coil.
      • Use the removed screw to push the terminal block out of the plastic DIN housing.
      • Note the “1”, “2”, and ground “⏚” symbols.
        • For DC DIN Coils, connect “1” to your positive lead and “2” to your negative lead.
        • For AC DIN Coils, connect “1” to your HOT lead, “2” to your NEUTRAL lead, and “⏚” to your ground lead, if required.
  • To Connect a Grommet Coil:
    • For DC Coils, connect the red wire to your positive lead and the black wire to your negative lead.
    • For AC Coils, connect the black wire to your HOT lead and the white wire to your NEUTRAL lead.
    • For Coils provided with Molded Cables, the color of the wire indicates the type of lead:
      • GREEN = Ground Wire
      • BLUE = Positive or HOT Wire
      • BROWN = Negative or Neutral Wire
Flow Rate

Additional information

Part No.

2H012-1/8, 2H016-1/4

Reviews

There are no reviews yet.

Be the first to review “Solenoid Valve Specifications and Dimensions: 2H012-016 Series”

Your email address will not be published. Required fields are marked *