Solenoid Valve Specifications and Dimensions: 2MS120-500 Series
Price range: $258.35 through $912.34
Description
| Specifications | |||||||||
| Model | 2MS120-3/8 | 2MS150-1/2 | 2MS200-3/4 | 2MS250-1 | 2MS320-1 1/4 | 2MS400-1 1/2 | 2MS500-2 | ||
| Port Size | 3/8″ NPT | 1/2″ NPT | 3/4″ NPT | 1″ NPT | 1 1/4″ NPT | 1 1/2″ NPT | 2″ NPT | ||
| Orifice | 12mm | 15mm | 20mm | 25mm | 32mm | 40mm | 50mm | ||
| Cv | 4.5 | 4.5 | 7.6 | 12 | 22 | 30 | 48 | ||
| Valve Type | 2-Way | ||||||||
| Action | Pilot Piston | ||||||||
| De-Energized State | Normally Closed (NC) | ||||||||
| Body Material | 304 Stainless Steel | ||||||||
| Seal Material | PTFE (Teflon) | ||||||||
| Operating Temperature |
|
||||||||
| Operating Pressure (Standard) | 6 PSI to 230 PSI | ||||||||
| Medium Pressure Option (M) |
|
||||||||
| High Pressure Option (H) | 87 PSI to 1450 PSI | 87 PSI to 1160 PSI | |||||||
| Electrical Connection |
|
||||||||
| Coil Power |
|
||||||||
| Voltage Options | 12VDC
24VDC 24VAC (50/60Hz) 110/120VAC (50/60Hz) 220/240VAC (50/60Hz) |
||||||||
| Voltage Tolerance | ±10% of Specified Voltage | ||||||||
| Ingress Protection | IP65 | ||||||||
| Insulation Class | H Class | ||||||||
| Coil Duty | 100% ED, Continuous Duty | ||||||||
| Installation | No Orientation Requirement | ||||||||
| Service | Liquid, Air, Inert Gas, Steam, Vacuum | ||||||||
| Download Drawings | ||||||||||||||
| 3D STEP | 2MS120-3/8 | 2MS150-1/2 | 2MS200-3/4 | 2MS250-1 | 2MS320-1 1/4 | 2MS400-1 1/2 | 2MS500-2 | |||||||
| 3D PDF | 2MS120-3/8 | 2MS150-1/2 | 2MS200-3/4 | 2MS250-1 | 2MS320-1 1/4 | 2MS400-1 1/2 | 2MS500-2 | |||||||
| 3D Solidworks | 2MS120-3/8 | 2MS150-1/2 | 2MS200-3/4 | 2MS250-1 | 2MS320-1 1/4 | 2MS400-1 1/2 | 2MS500-2 | |||||||
| 2D AutoCAD | 2MS120-3/8 | 2MS150-1/2 | 2MS200-3/4 | 2MS250-1 | 2MS320-1 1/4 | 2MS400-1 1/2 | 2MS500 | |||||||
Dimensions
| 2MS120-500 & 2MSO120-500 Series Solenoid Valve Dimensions | ||||||
| Model | Port | A | B | C | D | E |
| 2MS120-3/8 | 3/8″ NPT | 137.8 | 124.3 | 70.0 | 62.9 | 54.3 |
| 2MS150-1/2 | 1/2″ NPT | 137.8 | 124.3 | 70.0 | 62.9 | 54.3 |
| 2MS200-3/4 | 3/4″ NPT | 149.1 | 132.4 | 73.8 | 62.9 | 58.4 |
| 2MS250-1 | 1″ NPT | 158.6 | 138.6 | 92.3 | 62.9 | 69.6 |
| 2MS320-1 1/4 | 1 1/4″ NPT | 177.9 | 150.9 | 116.1 | 62.9 | 84.7 |
| 2MS400-1 1/2 | 1 1/2″ NPT | 182.4 | 153.4 | 122.0 | 62.9 | 90.5 |
| 2MS500-2 | 2″ NPT | 198.9 | 163.9 | 167.9 | 62.9 | 117.6 |
| Dimensions for Reference Use Only: Units in mm | ||||||
2MS Series: 2/2 Pilot Piston Normally Closed Solenoid Valve
The 2MS Series valves are 2 way, normally closed, internal pilot piston solenoid valves. When the coil is energized, it lifts the pilot valve off the top of the piston ring and pressure under the piston ring forces the piston up to open the main valve orifice. When the coil is de-energized, the pilot valve returns to close the pilot orifice and pressure across the piston ring is equalized through a timing orifice in the side of the piston or in the valve body. The piston spring returns the piston to close the main valve orifice.ALL standard valves are supplied with Continuous Duty Coils of the proper class of insulation for the service indicated on the valve. It is normal for the coil temperature may become hot after being energized for extended periods. Smoke or burning odor indicates excessive coil temperature and the power should be disconnected to the coil immediately.
SERVICE LIFE: The service life of the solenoid valve depends on the operating conditions such as pressure, temperature, type of medium, and the voltage.
Electrical Coil Connections
- To Connect a DIN Coil:
- Remove the Philips screw from the plastic housting & unplug from the DIN coil.
- Use the removed screw to push the terminal block out of the plastic DIN housing.
- Note the “1”, “2”, and ground “⏚” symbols.
- For DC DIN Coils, connect “1” to your positive lead and “2” to your negative lead.
- For AC DIN Coils, connect “1” to your HOT lead, “2” to your NEUTRAL lead, and “⏚” to your ground lead, if required.
- To Connect a Grommet Coil:
- For DC Coils, connect the red wire to your positive lead and the black wire to your negative lead.
- For AC Coils, connect the black wire to your HOT lead and the white wire to your NEUTRAL lead.
- For Coils provided with Molded Cables, the color of the wire indicates the type of lead:
- GREEN = Ground Wire
- BLUE = Positive or HOT Wire
- BROWN = Negative or Neutral Wire
Additional information
| Part No. | 2MS120-3/8, 2MS150-1/2, 2MS200-3/4, 2MS250-1, 2MS320-1 1/4, 2MS400-1 1/2, 2MS500-2 |
|---|






Reviews