Description
| Specifications |
| Stainless Steel |
2SO160-3/8 |
2SO160-1/2 |
2SO200 |
2SO250 |
2SO350 |
2SO400 |
2SO500 |
| Brass |
2WO160-3/8 |
2WO160-1/2 |
2WO200 |
2WO250 |
2WO350 |
2WO400 |
2WO500 |
| Port Size |
3/8″ NPT |
1/2″ NPT |
3/4″ NPT |
1″ NPT |
1 1/4″ NPT |
1 1/2″ NPT |
2″ NPT |
| Orifice |
16mm |
16mm |
20mm |
25mm |
35mm |
40mm |
50mm |
| Cv |
4.8 |
4.8 |
7.6 |
12 |
24 |
29 |
48 |
| Valve Type |
2-Way |
| Action |
Semi-Direct Lift Diaphragm, Uni-Directional, Zero Differential |
| De-Energized State |
Normally Open (NO) |
| Body Material |
| 2S Series:
2W Series:
Armature Assembly: |
304 Stainless Steel
Brass
Stainless Steel |
|
| Seal Material |
| Standard Option:
Upgrade Options: |
NBR (Buna)
Viton (FKM)
EPDM |
|
| Operating Temperature |
| Media with NBR Seal:
Media with Viton Seal:
Ambient: |
14°F to 176°F (-10°C to 80°C)
5°F to 248°F (-15°C to 120°C)
23°F to 113°F (-5°C to 45°C) |
|
| Operating Pressure |
| Standard Option:
Upgrade Option: |
Vacuum to 90PSI
Vacuum to 150PSI |
|
| Electrical Connection |
DIN 43650A |
| Standard Coil Power |
| AC Coil:
DC Coil: |
28VA
25-40W |
|
| Voltage Options |
|
12VDC
24VDC
24VAC (50/60Hz)
110/120VAC (50/60Hz)
220/240VAC (50/60Hz) |
|
| Voltage Tolerance |
±10% of Specified Voltage |
| Ingress Protection |
IP65 |
| Insulation Class |
H Class |
| Coil Duty |
100% ED, Continuous Duty |
| Installation |
No Orientation Requirement
Optimum Position: Flow Horizontal and Solenoid Vertical |
| Service |
Liquid, Water, Oil, Air, Gas, Inert Gas, Vacuum |


<
| 2SO160-500 & 2WO160-500 Series Solenoid Valve Dimensions |
| Model |
Port |
A |
B |
C |
D |
E |
| 2SO160-3/8 |
3/8″ NPT |
104.3 |
90.8 |
69.5 |
53.9 |
56.0 |
| 2WO160-3/8 |
101.8 |
88.3 |
68.2 |
53.9 |
56.7 |
| 2SO160-1/2 |
1/2″ NPT |
103.7 |
90.2 |
69.0 |
53.9 |
56.0 |
| 2WO160-1/2 |
102.0 |
88.5 |
68.0 |
53.9 |
56.7 |
| 2SO200-3/4 |
3/4″ NPT |
110.2 |
94.0 |
72.0 |
53.9 |
56.0 |
| 2WO200-3/4 |
109.1 |
93.0 |
71.3 |
53.9 |
56.7 |
| 2SO250-1 |
1″ NPT |
120.9 |
100.9 |
97.5 |
53.9 |
76.5 |
| 2WO250-1 |
118.9 |
98.9 |
89.2 |
53.9 |
77.0 |
| 2SO350-1 1/4 |
1 1/2″ NPT |
148.6 |
121.6 |
115.5 |
62.9 |
85.6 |
| 2WO350-1 1/4 |
147.0 |
120.0 |
111.0 |
62.9 |
85.0 |
| 2SO400-1 1/2 |
1 1/4″ NPT |
155.6 |
126.6 |
122.4 |
62.9 |
90.0 |
| 2WO400-1 1/2 |
153.7 |
125.7 |
120.0 |
62.9 |
89.5 |
| 2SO500-2 |
2″ NPT |
175.2 |
140.2 |
166.0 |
62.9 |
117.5 |
| 2WO500-2 |
172.1 |
138.1 |
154.8 |
62.9 |
111.8 |
| Dimensions for Reference Use Only: Units in mm |
|
2SO & 2WO Series 2/2 Direct Lift Diaphragm Normally Open Solenoid Valve:
This valve is a two-way, normally open, direct-lift valve and does not require a minimum differential pressure to operate. As shown in the diagrams below, when the coil is de-energized (left diagram), the spring force holds the diaphragm in place above the main orifice, allowing the working medium to flow freely through the valve. When the valve is energized, the diaphragm is pushed onto the main orifice, sealing the valve. The working medium supplies additional sealing pressure above the diaphram, reducing strain on the solenoid coil. This is accomplished via a small bleed orifice in the diaphragm which allows the working medium to pass through and pressurize the diaphragm from above while the valve is closed. The working medium and flow direction are indicated in purple in the diagrams.
ALL standard valves are supplied with Continuous Duty Coils of the proper class of insulation for the service indicated on the valve. It is normal for the coil temperature may become hot after being energized for extended periods. Smoke or burning odor indicates excessive coil temperature and the power should be disconnected to the coil immediately.
SERVICE LIFE: The service life of the solenoid valve depends on the operating conditions such as pressure, temperature, type of medium, and the voltage.

Electrical Coil Connections
-
- To Connect a DIN Coil:
- Remove the Philips screw from the plastic housting & unplug from the DIN coil.
- Use the removed screw to push the terminal block out of the plastic DIN housing.
- Note the “1”, “2”, and ground “⏚” symbols.
- For DC DIN Coils, connect “1” to your positive lead and “2” to your negative lead.
- For AC DIN Coils, connect “1” to your HOT lead, “2” to your NEUTRAL lead, and “⏚” to your ground lead, if required.
- To Connect a Grommet Coil:
- For DC Coils, connect the red wire to your positive lead and the black wire to your negative lead.
- For AC Coils, connect the black wire to your HOT lead and the white wire to your NEUTRAL lead.
- For Coils provided with Molded Cables, the color of the wire indicates the type of lead:
- GREEN = Ground Wire
- BLUE = Positive or HOT Wire
- BROWN = Negative or Neutral Wire