Solenoid Valve Specifications and Dimensions: 2SO160-500 and 2WO160-500 Series

Price range: $170.80 through $618.98

Description

Specifications
Stainless Steel 2SO160-3/8 2SO160-1/2 2SO200 2SO250 2SO350 2SO400 2SO500
Brass 2WO160-3/8 2WO160-1/2 2WO200 2WO250 2WO350 2WO400 2WO500
Port Size 3/8″ NPT 1/2″ NPT 3/4″ NPT 1″ NPT 1 1/4″ NPT 1 1/2″ NPT 2″ NPT
Orifice 16mm 16mm 20mm 25mm 35mm 40mm 50mm
Cv 4.8 4.8 7.6 12 24 29 48
Valve Type 2-Way
Action Semi-Direct Lift Diaphragm, Uni-Directional, Zero Differential
De-Energized State Normally Open (NO)
Body Material
2S Series:

2W Series:

Armature Assembly:

304 Stainless Steel

Brass

Stainless Steel

Seal Material
Standard Option:

Upgrade Options:

NBR (Buna)

Viton (FKM)

EPDM

Operating Temperature
Media with NBR Seal:

Media with Viton Seal:

Ambient:

14°F to 176°F (-10°C to 80°C)

5°F to 248°F (-15°C to 120°C)

23°F to 113°F (-5°C to 45°C)

Operating Pressure
Standard Option:

Upgrade Option:

Vacuum to 90PSI

Vacuum to 150PSI

Electrical Connection DIN 43650A
Standard Coil Power
AC Coil:

DC Coil:

28VA

25-40W

Voltage Options
12VDC

24VDC

24VAC (50/60Hz)

110/120VAC (50/60Hz)

220/240VAC (50/60Hz)

Voltage Tolerance ±10% of Specified Voltage
Ingress Protection IP65
Insulation Class H Class
Coil Duty 100% ED, Continuous Duty
Installation No Orientation Requirement

Optimum Position: Flow Horizontal and Solenoid Vertical

Service Liquid, Water, Oil, Air, Gas, Inert Gas, Vacuum

 

Download Drawings
3D STEP 2SO160-3/8 2SO160-1/2 2SO200 2SO250 2SO350 2SO400 2SO500
2WO160-3/8 2WO160-1/2 2WO200 2WO250 2WO350 2WO400 2WO500
3D PDF 2SO160-3/8 2SO160-1/2 2SO200 2SO250 2SO350 2SO400 2SO500
2WO160-3/8 2WO160-1/2 2WO200 2WO250 2WO350 2WO400 2WO500
3D Solidworks 2SO160-3/8 2SO160-1/2 2SO200 2SO250 2SO350 2SO400 2SO500
2WO160-3/8 2WO160-1/2 2WO200 2WO250 2WO350 2WO400 2WO500
2D AutoCAD 2SO160-3/8 2SO160-1/2 2SO200 2SO250 2SO350 2SO400 2SO500
2WO160-3/8 2WO160-1/2 2WO200 2WO250 2WO350 2WO400 2WO500

 

 

<

2SO160-500 & 2WO160-500 Series Solenoid Valve Dimensions
Model Port A B C D E
2SO160-3/8 3/8″ NPT 104.3 90.8 69.5 53.9 56.0
2WO160-3/8 101.8 88.3 68.2 53.9 56.7
2SO160-1/2 1/2″ NPT 103.7 90.2 69.0 53.9 56.0
2WO160-1/2 102.0 88.5 68.0 53.9 56.7
2SO200-3/4 3/4″ NPT 110.2 94.0 72.0 53.9 56.0
2WO200-3/4 109.1 93.0 71.3 53.9 56.7
2SO250-1 1″ NPT 120.9 100.9 97.5 53.9 76.5
2WO250-1 118.9 98.9 89.2 53.9 77.0
2SO350-1 1/4 1 1/2″ NPT 148.6 121.6 115.5 62.9 85.6
2WO350-1 1/4 147.0 120.0 111.0 62.9 85.0
2SO400-1 1/2 1 1/4″ NPT 155.6 126.6 122.4 62.9 90.0
2WO400-1 1/2 153.7 125.7 120.0 62.9 89.5
2SO500-2 2″ NPT 175.2 140.2 166.0 62.9 117.5
2WO500-2 172.1 138.1 154.8 62.9 111.8
Dimensions for Reference Use Only: Units in mm
2SO & 2WO Series 2/2 Direct Lift Diaphragm Normally Open Solenoid Valve:

This valve is a two-way, normally open, direct-lift valve and does not require a minimum differential pressure to operate. As shown in the diagrams below, when the coil is de-energized (left diagram), the spring force holds the diaphragm in place above the main orifice, allowing the working medium to flow freely through the valve. When the valve is energized, the diaphragm is pushed onto the main orifice, sealing the valve. The working medium supplies additional sealing pressure above the diaphram, reducing strain on the solenoid coil. This is accomplished via a small bleed orifice in the diaphragm which allows the working medium to pass through and pressurize the diaphragm from above while the valve is closed. The working medium and flow direction are indicated in purple in the diagrams.

ALL standard valves are supplied with Continuous Duty Coils of the proper class of insulation for the service indicated on the valve. It is normal for the coil temperature may become hot after being energized for extended periods. Smoke or burning odor indicates excessive coil temperature and the power should be disconnected to the coil immediately.
SERVICE LIFE: The service life of the solenoid valve depends on the operating conditions such as pressure, temperature, type of medium, and the voltage.

Electrical Coil Connections

    • To Connect a DIN Coil:
      • Remove the Philips screw from the plastic housting & unplug from the DIN coil.
      • Use the removed screw to push the terminal block out of the plastic DIN housing.
      • Note the “1”, “2”, and ground “⏚” symbols.
        • For DC DIN Coils, connect “1” to your positive lead and “2” to your negative lead.
        • For AC DIN Coils, connect “1” to your HOT lead, “2” to your NEUTRAL lead, and “⏚” to your ground lead, if required.
  • To Connect a Grommet Coil:
    • For DC Coils, connect the red wire to your positive lead and the black wire to your negative lead.
    • For AC Coils, connect the black wire to your HOT lead and the white wire to your NEUTRAL lead.
    • For Coils provided with Molded Cables, the color of the wire indicates the type of lead:
      • GREEN = Ground Wire
      • BLUE = Positive or HOT Wire
      • BROWN = Negative or Neutral Wire

Additional information

Part No.

2WO160-3/8, 2WO160-1/2, 2WO200-3/4, 2WO250-1, 2WO350-1 1/4, 2WO400-1 1/2, 2WO500-2

Reviews

There are no reviews yet.

Be the first to review “Solenoid Valve Specifications and Dimensions: 2SO160-500 and 2WO160-500 Series”

Your email address will not be published. Required fields are marked *