Solenoid Valve Specifications and Dimensions: 2SO160-500 and 2WO160-500 Series
Price range: $221.96 through $839.27
Description
Specifications
| Stainless Steel | 2SO160-3/8 | 2SO160-1/2 | 2SO200 | 2SO250 | 2SO350 | 2SO400 | 2SO500 |
| Brass | 2WO160-3/8 | 2WO160-1/2 | 2WO200 | 2WO250 | 2WO350 | 2WO400 | 2WO500 |
| Port Size | 3/8″ NPT | 1/2″ NPT | 3/4″ NPT | 1″ NPT | 1 1/4″ NPT | 1 1/2″ NPT | 2″ NPT |
| Orifice | 16mm | 16mm | 20mm | 25mm | 35mm | 40mm | 50mm |
| Cv | 4.8 | 4.8 | 7.6 | 12 | 24 | 29 | 48 |
| Valve Type | 2-Way | ||||||
| Action | Semi-Direct Lift Diaphragm, Uni-Directional, Zero Differential | ||||||
| De-Energized State | Normally Open (NO) | ||||||
| Body Material | 2S Series: Stainless Steel
2W Series: Brass |
||||||
| Armature Assembly | 304 Stainless Steel | ||||||
| Seal Material | Standard Option: NBR (Buna)
Upgrade Options: Viton (FKM), EPDM |
||||||
| Operating Temperature | Media with NBR Seal: 14°F to 176°F (-10°C to 80°C)
Media with Viton Seal: 5°F to 248°F (-15°C to 120°C) Ambient: 23°F to 113°F (-5°C to 45°C) |
||||||
| Operating Pressure | Standard Option: Vacuum to 90PSI
Upgrade Option: Vacuum to 150PSI |
||||||
| Electrical Connection | DIN 43650A Standard | ||||||
| Coil Power | AC Coil: 28VA
DC Coil: 25-40W |
||||||
| Voltage Options | 12VDC, 24VDC, 24VAC (50/60Hz), 110/120VAC (50/60Hz), 220/240VAC (50/60Hz) | ||||||
| Voltage Tolerance | ±10% of Specified Voltage | ||||||
| Ingress Protection | IP65 | ||||||
| Insulation Class | H Class | ||||||
| Coil Duty | 100% ED, Continuous Duty | ||||||
| Installation | No Orientation Requirement. Optimum Position: Flow Horizontal and Solenoid Vertical | ||||||
| Service | Liquid, Water, Oil, Air, Gas, Inert Gas, Vacuum | ||||||
| Download Drawings | |||||||
| 3D STEP | 2SO160-3/8 | 2SO160-1/2 | 2SO200 | 2SO250 | 2SO350 | 2SO400 | 2SO500 |
| 2WO160-3/8 | 2WO160-1/2 | 2WO200 | 2WO250 | 2WO350 | 2WO400 | 2WO500 | |
| 3D PDF | 2SO160-3/8 | 2SO160-1/2 | 2SO200 | 2SO250 | 2SO350 | 2SO400 | 2SO500 |
| 2WO160-3/8 | 2WO160-1/2 | 2WO200 | 2WO250 | 2WO350 | 2WO400 | 2WO500 | |
| 3D Solidworks | 2SO160-3/8 | 2SO160-1/2 | 2SO200 | 2SO250 | 2SO350 | 2SO400 | 2SO500 |
| 2WO160-3/8 | 2WO160-1/2 | 2WO200 | 2WO250 | 2WO350 | 2WO400 | 2WO500 | |
| 2D AutoCAD | 2SO160-3/8 | 2SO160-1/2 | 2SO200 | 2SO250 | 2SO350 | 2SO400 | 2SO500 |
| 2WO160-3/8 | 2WO160-1/2 | 2WO200 | 2WO250 | 2WO350 | 2WO400 | 2WO500 | |
Dimensions
| 2SO160-500 & 2WO160-500 Series Solenoid Valve Dimensions | |||||||
| Model | Port | A | B | C | D | E | |
| 2SO160-3/8 | 3/8″ NPT | 104.3 | 90.8 | 69.5 | 53.9 | 56.0 | |
| 2WO160-3/8 | 101.8 | 88.3 | 68.2 | 53.9 | 56.7 | ||
| 2SO160-1/2 | 1/2″ NPT | 103.7 | 90.2 | 69.0 | 53.9 | 56.0 | |
| 2WO160-1/2 | 102.0 | 88.5 | 68.0 | 53.9 | 56.7 | ||
| 2SO200-3/4 | 3/4″ NPT | 110.2 | 94.0 | 72.0 | 53.9 | 56.0 | |
| 2WO200-3/4 | 109.1 | 93.0 | 71.3 | 53.9 | 56.7 | ||
| 2SO250-1 | 1″ NPT | 120.9 | 100.9 | 97.5 | 53.9 | 76.5 | |
| 2WO250-1 | 118.9 | 98.9 | 89.2 | 53.9 | 77.0 | ||
| 2SO350-1 1/4 | 1 1/2″ NPT | 148.6 | 121.6 | 115.5 | 62.9 | 85.6 | |
| 2WO350-1 1/4 | 147.0 | 120.0 | 111.0 | 62.9 | 85.0 | ||
| 2SO400-1 1/2 | 1 1/4″ NPT | 155.6 | 126.6 | 122.4 | 62.9 | 90.0 | |
| 2WO400-1 1/2 | 153.7 | 125.7 | 120.0 | 62.9 | 89.5 | ||
| 2SO500-2 | 2″ NPT | 175.2 | 140.2 | 166.0 | 62.9 | 117.5 | |
| 2WO500-2 | 172.1 | 138.1 | 154.8 | 62.9 | 111.8 | ||
| Dimensions for Reference Use Only: Units in mm | |||||||
This valve is a two-way, normally open, direct-lift valve and does not require a minimum differential pressure to operate. As shown in the diagrams below, when the coil is de-energized (left diagram), the spring force holds the diaphragm in place above the main orifice, allowing the working medium to flow freely through the valve. When the valve is energized, the diaphragm is pushed onto the main orifice, sealing the valve. The working medium supplies additional sealing pressure above the diaphram, reducing strain on the solenoid coil. This is accomplished via a small bleed orifice in the diaphragm which allows the working medium to pass through and pressurize the diaphragm from above while the valve is closed. The working medium and flow direction are indicated in purple in the diagrams.
SERVICE LIFE: The service life of the solenoid valve depends on the operating conditions such as pressure, temperature, type of medium, and the voltage.

Electrical Coil Connections
To Connect a DIN Coil:
- Remove the Philips screw from the plastic housting & unplug from the DIN coil.
- Use the removed screw to push the terminal block out of the plastic DIN housing.
- Note the “1”, “2”, and ground “⏚” symbols.
-
-
-
- For DC DIN Coils, connect “1” to your positive lead and “2” to your negative lead.
- For AC DIN Coils, connect “1” to your HOT lead, “2” to your NEUTRAL lead, and “⏚” to your ground lead, if required.
-
-
To Connect a Grommet Coil:
- For DC Coils, connect the red wire to your positive lead and the black wire to your negative lead.
- For AC Coils, connect the black wire to your HOT lead and the white wire to your NEUTRAL lead.
- For Coils provided with Molded Cables, the color of the wire indicates the type of lead:
-
-
- GREEN = Ground Wire
- BLUE = Positive or HOT Wire
- BROWN = Negative or Neutral Wire
-
Additional information
| Part No. | 2SO160-3/8, 2SO160-1/2, 2SO200-3/4, 2SO250-1, 2SO350-1 1/4, 2SO400-1 1/2, 2SO500-2 |
|---|






Reviews
There are no reviews yet.