Solenoid Valve Specifications and Dimensions: 3S035 Series

$337.60

Port Size (NPT)

1/4″ NPT

1/4″ NPT

Voltage (Explosion Proof)

2-ATEX = 24VDC

2A-ATEX = 24VAC

3-ATEX = 110VAC

4-ATEX = 220VAC

Electrical Connection

2W200C ATEX Explosion Proof Coil

Cv/Orifice

Cv = 0.23

Orifice = 2mm

Cv = 0.5

Orifice = 3.5mm

Services

Air, Liquid, Oil, Water

Features

3 Way Direct Acting

Normally Closed or Open

Valve Body: Stainless Steel

Seal: Viton

Temperature: 5 to 248°F (-15 to 120°C)

Operating Pressure (2mm Orifice): 0 to 100PSI

Operating Pressure (3.5mm Orifice): 0 to 50PSI

Response Time <20msec

Coil Power: 13 to 20W

SKU: N/A Category:

Description

Valve Model 3S035
Valve Type 3 Way Normally Closed (NC) or Normally Open (NO)
Action Direct Acting
Cv (Orifice) 0.5 (3.5mm NC Port, 2.5mm NO Port)
Operating Pressure (PSI) 0  to 80 PSI
Operating Temperature (°C) -10 to 120°C
Port Size (NPT) 1/4
Body Materials Stainless Steel
Seal Materials: Viton (Options: EPDM, NBR)
Coil Protection Insulation Class H Class IP65
Coil Duty 100% ED
Coil Power 14W
Electrical Connections DIN
Service Air, Gas, Liquid, Vacuum

2/3 Direct Acting Solenoid Valve Normally Closed (3S035 Series)

As shown below, when the valve is de-energized (left diagram), the plunger under the force of spring seals the main orifice, and port CYL connects with port EX. When the valve is energized (right diagram), the coil magnetic force pulls back the plunger and closes port EX, and connects port IN to CYL.

To operate the 3S035 as a normally open diverter , you need to connect the supply air to Port No 1. The Top Port is the normally open port and Port No. 2 is the normally closed port. In the configuration, air goes from Port No. 1 to the Top Port when the valve is de-energized. When it is energized air will go from Port No. 1 to Port No. 2 and the Top Port will be shut off.

To operate the 3S035 as a normally open on/off valve, you need to connect the supply air to the Top Port. The Port No.1 is the normally open port. In the configuration, air goes from the Top Port to Port No. 1 when the valve is de-energized. When it is energized the Top Port is shut off, and Port No. 1 will be exhausted to Port No. 2. To operate the 3S035 as a normally open diverter , you need to connect the supply air to Port No 1. The Top Port is the normally open port and Port No. 2 is the normally closed port. In the configuration, air goes from Port No. 1 to the Top Port when the valve is de-energized. When it is energized air will go from Port No. 1 to Port No. 2 and the Top Port will be shut off.

Electrical Coil Connections
For DIN Coil To connect DIN coil:

1. Remove the Philip screw from the plastic housing and unplug it from the DIN coil.

2. From the screw opening, push the terminal block out from the plastic housing.

3. Note the 1, 2 and ground markings on underside of DIN enclosure.

4. For DC DIN Coil, Connect 1 to Positive, 2 to Negative.

5. For AC DIN Coil, connect 1 to HOT wire, 2 to Neutral wire, and if required connect ground to ground wire.

For Grommet Coil To connect Grommet coil:

1.  For DC Coil, connect one of the two wires to Positive, and the other wire to Negative.

2. For AC Coil, connect one of the two wires to HOT wire, and the other wire to neutral wire.