Slow Closing, Anti Water Hammer Solenoid Valve Specifications and Dimensions: 2D150-500-2DS150-500 Series

Price range: $153.12 through $635.08

  • Port Size (NPT): 1/2″ NPT

    3/4″ NPT

    1″ NPT

    1 1/4″ NPT

    1 1/2″ NPT

    2″ NPT

  • Voltage:
    • 1 = 12VDC
    • 2 = 24VDC
    • 2A = 24VAC
    • 3 = 110VAC
    • 4 = 220VAC
    • ATEX = Explosion Proof Coil
  • Electrical Connection:
    • D = DIN
  • Cv/Orifice:
    • Cv = 3.7

      Orifice = 15mm

    • Cv = 7

      Orifice = 20mm

    • Cv = 11.1

      Orifice = 25mm

    • Cv = 14

      Orifice = 32mm

    • Cv = 24.5

      Orifice = 40mm

    • Cv = 35

      Orifice = 50mm

  • Services:
    • Air, Oil, Gas, Water
  • Features:
    • 2-Way, Slow Closing

      Pilot Diaphragm

      Normally Closed

      Option: Normally Open

      Body: 304 Stainless Steel Option: 316 Stainless Steel

      Seal: NBR

      Option: FKM, EPDM

      Operating Temperature:

      NBR Seal: 14 to 176°F

      FKM Seal: 14 to 266°F

      Ambient Temperature:

      23 to 110°F

      Operating Pressure:

      AC: 4 to 175PSI

      DC: 4 to 145PSI

      Coil Power: 12 to 20W

      Coil: Class H, IP65

  • Valve Symbol / Catalog:

Data Sheet:

2D150-500.PDF

Download Drawings

Description

Specifications
Brass 2D150-1/2 2D200-3/4 2D250-1 2D320-1 1/4 2D400-1 1/2 2D500-2
Stainless Steel 2DS150-1/2 2SD200-3/4 2DS250-1 2DS320-1 1/4 2DS400-1 1/2 2DS500-2
Port Size (NPT) 1/2″ NPT 3/4″ NPT 1″ NPT 1 1/4″ NPT 1 1/2″ NPT 2″ NPT
Orifice 15mm 20mm 25mm 32mm 40mm 50mm
Cv 3.7 7 11.1 24 30 48
Valve Type 2-Way
Action Pilot Diaphragm Anti-Hammering, Slow Closing
De-Energized State Normally Closed (NC)
Body Material 2D Series: Brass

2DS Series: 304 Stainless Steel

Seal Material NBR (Buna), Viton (FKM), EPDM
Operating Temperature Media with NBR Seal: 14°F to 176°F (-10°C to 80°C)

Media with Viton Seal: 14°F to 266°F (-10°C to 130°C)

Ambient: 23°F to 110°F (-5°C to 43°C)

Operating Pressure AC Coil: 4 PSI to 175 PSI

DC Coil: 4 PSI to 145 PSI

Electrical Connection DIN 43650A

ATEX Explosion Proof Coil (optional)

Coil Power AC Coil: 28VA

DC Coil: 12–20W

Voltage Options 12VDC, 24VDC, 24VAC (50/60Hz), 110/120VAC (50/60Hz), 220/240VAC (50/60Hz)
Voltage Tolerance ±10% of Specified Voltage
Ingress Protection IP65
Insulation Class H Class
Coil Duty 100% ED, Continuous Duty
Installation No Orientation Requirement
Service Liquid, Water, Oil, Air
Download Drawings
3D STEP 2D150-1/2 2D200-3/4 2D250-1 2D320-1 1/4 2D400-1 1/2 2D500-2
2DS150-1/2 2DS200-3/4 2DS250-1 2DS320-1 1/4 2DS400-1 1/2 2DS500-2
3D PDF 2D150-1/2 2D200-3/4 2D250-1 2D320-1 1/4 2D400-1 1/2 2D500-2
2DS150-1/2 2DS200-3/4 2DS250-1 2DS320-1 1/4 2DS400-1 1/2 2DS500-2
3D Solidworks 2D150-1/2 2D200-3/4 2D250-1 2D320-1 1/4 2D400-1 1/2 2D500-2
2DS150-1/2 2DS200-3/4 2DS250-1 2DS320-1 1/4 2DS400-1 1/2 2DS500-2
2D AutoCAD 2D150-1/2 2D200-3/4 2D250-1 2D320-1 1/4 2D400-1 1/2 2D500-2
2DS150-1/2 2DS200-3/4 2DS250-1 2DS320-1 1/4 2DS400-1 1/2 2DS500-2

Brass Stainless Steel Port A B C D
2D150-1/2 2DS150-1/2 1/2″ NPT 101.4 87.4 80.0 44.5
2D200-3/4 2DS200-3/4 3/4″ NPT 111.6 94.6 86.5 50.9
2D250-1 2DS250-1 1″ NPT 121.4 100.4 106.5 65.8
2D320-1 1/4 2DS320-1 1/4 1 1/4″ NPT 131.4 105.9 130.0 84.4
2D400-1 1/2 2DS400-1 1/2 1 1/2″ NPT 146.4 117.4 144.5 96.0
2D500-2 2DS500-2 2″ NPT 161.6 126.1 177.4 125.0

Dimensions for Reference Use Only: Units in mm

Installation and Operation

To connect the valve Inlet and Outlet:

Connect the inlet and outlet in the direction of the arrow marked on the valve.

To install coil:

Put the coil onto the armature tube of the valve. Put the lock-washer and nut onto the armature tube. Hand tighten the nut, then use a wrench to tighten the nut to a quarter turn; do not over-tighten the nut, it may cause the armature tube to fail pre-maturely.

To connect DIN coil:

1. Remove the Philip screw from the plastic housing and unplug it from the DIN coil.

2. From the screw opening, push the terminal block out from the plastic housing.

3. Note the 1, 2 and ground markings on underside of DIN enclosure.

4. For DC DIN Coil, Connect 1 to Positive, 2 to Negative.

5. For AC DIN Coil, connect 1 to HOT wire, 2 to Neutral wire, and if required connect.

6. Do not energize the coil without installing it onto the valve, it will burn the coil and create fire hazards.

Safety Note: Standard valves are supplied with continuous duty coils. The proper class of insulation for the service is indicated on the coil. The coil temperature may become hot after being energized for extended periods, but it is normal. Do not energize the coil without installing it onto the valve or connect the coil to a wrong voltage, as it may overheat and damage the coil; although the coil is made of flame retarded material, misuse of the coil in this manner could create fire hazards and generate smoke or burning odor which indicates excessive coil temperature and should disconnect the power to the coil immediately.

Operation: 2D150-500 Series 2/2 Pilot Operated Diaphragm Solenoid Valve NC

To open: when the valve receives an electrical signal, a magnetic field is formed which attracts the plunger covering the pilot orifice to lift off, causing system pressure (holding the diaphragm/piston closed) to drop. As system pressure on the top of the diaphragm/piston is reduced, full system pressure on the other side of the diaphragm/piston acts to lift the diaphragm/piston away from the main orifice, which allows media flow through the valve. Since the bleed orifice is dimensionally smaller than the pilot orifice, the system pressure can t rebuild on the top of the diaphragm/piston as long as the pilot orifice remains open.

To close: when the valve is de-energized, it releases its hold on the plunger. Then the plunger drops and covers the main orifice. The system pressure builds up on the top of the diaphragm/piston through the bleed orifice, forcing the diaphragm/piston down until it covers the main orifice and stops media flow through the valve.

Additional information

Size

2DS150-1/2, 2DS200-3/4, 2DS250-1, 2DS320-1 1/4, 2DS400-1 1/2, 2DS500-2

Reviews