Solenoid Valve Specifications and Dimensions: 2S160-500 and 2W160-500 Series

Price range: $192.95 through $745.20

SKU: N/A Category:

Description

Specifications
Stainless Steel 2S160-3/8 2S160-1/2 2S200 2S250 2S350 2S400 2S500
Brass 2W160-3/8 2W160-1/2 2W200 2W250 2W350 2W400 2W500
Port Size 3/8″ NPT 1/2″ NPT 3/4″ NPT 1″ NPT 1 1/4″ NPT 1 1/2″ NPT 2″ NPT
Orifice 16mm 16mm 20mm 25mm 35mm 40mm 50mm
Cv 4.8 4.8 7.6 12 24 29 48
Valve Type 2-Way
Action Semi-Direct Lift Diaphragm, Uni-Directional, Zero Differential
De-Energized State Normally Closed (NC)
Body Material
2S Series:

2W Series:

Armature Assembly:

304 Stainless Steel

Brass

Stainless Steel

Seal Material
Standard Option:

Upgrade Options:

NBR (Buna)

Viton (FKM)

EPDM

Operating Temperature
Media with NBR Seal:

Media with Viton Seal:

Ambient:

14°F to 176°F (-10°C to 80°C)

5°F to 248°F (-15°C to 120°C)

23°F to 113°F (-5°C to 45°C)

Operating Pressure
AC Coil:

DC Coil:

Vacuum* to 150PSI

Vacuum* to 100PSI

*Larger than 29 in-Hg

Electrical Connection
Standard Option:

Upgrade Option:

DIN 43650A

ATEX Explosion Proof Coil

Standard Coil Power
Square Coil (2W200C)
AC Coil:

DC Coil:

28VA

12-20W

Rectangular Coil (2WO250C)
AC Coil:

DC Coil:

28VA

25-40W

Voltage Options
12VDC

24VDC

24VAC (50/60Hz)

110/120VAC (50/60Hz)

220/240VAC (50/60Hz)

Voltage Tolerance ±10% of Specified Voltage
Ingress Protection IP65
Insulation Class H Class
Coil Duty 100% ED, Continuous Duty
Installation No Orientation Requirement

Optimum Position: Flow Horizontal and Solenoid Vertical

Service Liquid, Water, Oil, Air, Gas, Inert Gas, Vacuum

 

 

Download Drawings
3D STEP 2S160-3/8 2S160-1/2 2S200 2S250 2S350 2S400 2S500
2W160-3/8 2W160-1/2 2W200 2W250 2W350 2W400 2W500
3D PDF 2S160-3/8 2S160-1/2 2S200 2S250 2S350 2S400 2S500
2W160-3/8 2W160-1/2 2W200 2W250 2W350 2W400 2W500
3D Solidworks 2S160-3/8 2S160-1/2 2S200 2S250 2S350 2S400 2S500
2W160-3/8 2W160-1/2 2W200 2W250 2W350 2W400 2W500
2D AutoCAD 2S160-3/8 2S160-1/2 2S200 2S250 2S350 2S400 2S500
2W160-3/8 2W160-1/2 2W200 2W250 2W350 2W400 2W500

Dimensions

Model Port A B C D E
2S160-3/8 3/8″ NPT 104.3 90.8 69.5 53.9 56.0
2W160-3/8 3/8″ NPT 101.8 88.3 68.2 53.9 56.7
2S160-1/2 1/2″ NPT 103.7 90.2 69.0 53.9 56.0
2W160-1/2 1/2″ NPT 102.0 88.5 68.0 53.9 56.7
2S200-3/4 3/4″ NPT 110.2 94.0 72.0 53.9 56.0
2W200-3/4 3/4″ NPT 109.1 93.0 71.3 53.9 56.7
2S250-1 1″ NPT 120.9 100.9 97.5 53.9 76.5
2W250-1 1″ NPT 118.9 98.9 89.2 53.9 77.0
2S350-1 1/4 1 1/2″ NPT 148.6 121.6 115.5 62.9 85.6
2W350-1 1/4 1 1/2″ NPT 147.0 120.0 111.0 62.9 85.0
2S400-1 1/2 1 1/4″ NPT 155.6 126.6 122.4 62.9 90.0
2W400-1 1/2 1 1/4″ NPT 153.7 125.7 120.0 62.9 89.5
2S500-2 2″ NPT 175.2 140.2 166.0 62.9 117.5
2W500-2 2″ NPT 172.1 138.1 154.8 62.9 111.8

 

2S & 2W Series 2/2 Direct Lift Diaphragm Normally Closed Solenoid Valve:

This valve is a two-way, normally closed, direct-lift valve and does not require a minimum differential pressure to operate. As shown in the diagrams below, when the coil is de-energized (left diagram), the plunger and flexible diaphragm sit on the main valve orifice. The working medium flows through a tiny “bleed orifice” and pressurizes the cavity above the diaphragm – this system pressure, along with the spring force, seals the valve. When the valve is energized, the diaphragm is pulled away from the main orifice, allowing fluid to flow through the valve. Since the bleed orifice is dimensionally smaller than the main orifice, the system pressure cannot rebuilt on the top of the diaphragm as long as the main orifice remains open. The working medium and flow direction are indicated in purple in the diagrams.

ALL standard valves are supplied with Continuous Duty Coils of the proper class of insulation for the service indicated on the valve. It is normal for the coil temperature may become hot after being energized for extended periods. Smoke or burning odor indicates excessive coil temperature and the power should be disconnected to the coil immediately.

CAUTION: Do not energize the solenoid coil when it is not installed onto the valve. It may cause it to overheat and create a fire hazard.

SERVICE LIFE: The service life of the solenoid valve depends on the operating conditions such as pressure, temperature, type of medium, and the voltage.

Electrical Coil Connections

To Connect a DIN Coil:

  • Remove the Philips screw from the plastic housting & unplug from the DIN coil.
  • Use the removed screw to push the terminal block out of the plastic DIN housing.
  • Note the “1”, “2”, and ground “⏚” symbols.
        • For DC DIN Coils, connect “1” to your positive lead and “2” to your negative lead.
        • For AC DIN Coils, connect “1” to your HOT lead, “2” to your NEUTRAL lead, and “⏚” to your ground lead, if required.

To Connect a Grommet Coil:

  • For DC Coils, connect the red wire to your positive lead and the black wire to your negative lead.
  • For AC Coils, connect the black wire to your HOT lead and the white wire to your NEUTRAL lead.
  • For Coils provided with Molded Cables, the color of the wire indicates the type of lead:
      • GREEN = Ground Wire
      • BLUE = Positive or HOT Wire
      • BROWN = Negative or Neutral Wire

Additional information

Part No.

2S160-3/8, 2S160-1/2, 2S200-3/4, 2S250-1, 2S350-1 1/4, 2S400-1 1/2, 2S500-2

Reviews

There are no reviews yet.

Be the first to review “Solenoid Valve Specifications and Dimensions: 2S160-500 and 2W160-500 Series”

Your email address will not be published. Required fields are marked *