Solenoid Valve Specifications and Dimensions: 2S012-020-A Series

$52.94

Port Size (NPT)

1/8″ NPT

1/4″ NPT

1/8″ NPT

1/4″ NPT

Voltage

1 = 12VDC

2 = 24VDC

2A = 24VAC

3 = 110VAC

4 = 220VAC

E or ATEX = Explosion Proof Coil

Electrical Connection

G = Grommet

D = DIN (with LED)

Cv/Orifice

Cv = 0.05

Orifice = 1.2mm

Cv = 0.15

Orifice = 2.0mm

Services

Air, Liquid, Oil, Water

Features

2-Way, Normally Closed

Direct Acting

Body: Stainless Steel

Seal: NBR

Operating Temperature:

14 to 176°F

Operating Pressure:

0 to 200PSI

Coil Power: 3 to 6.5W

Response Time: <20msec Two Way NC Pneumatic Diagram

Data Sheet:

2S012-020-A.PDF

2S012-1/4A $47.69 1/4″ NPT

2S020-1/8A $47.69 1/8″ NPT Cv = 0.15

Orifice = 2.0mm 2-Way, Normally Closed

Direct Acting

Body: Stainless Steel

Seal: NBR

Operating Temperature:

14 to 176°F

Operating Pressure:

0 to 150PSI

Coil Power: 3 to 6.5W

Response Time: <20msec

Valve Symbol/Catalog

Two Way NC Pneumatic Diagram

Data Sheet:

2S012-020-A.PDF

 

SKU: N/A Category:

Description

Specifications
Model 2S012-1/8A 2S012-1/4A 2S020-1/8A 2S020-1/4A
Port Size 1/8″ NPT 1/4″ NPT 1/8″ NPT 1/4″ NPT
Orifice 1.2mm 2.0mm
Cv 0.05 0.15
Valve Type 2-Way
Action Direct Acting (Poppet)

Fast Response Time: <20msec

De-Energized State Normally Closed (NC)
Body Material
Valve Body:

Armature Assembly:

Stainless Steel

Stainless Steel

Seal Material
Standard Option:

Upgrade Option:

NBR (Buna)

Viton (FKM)

Operating Temperature
Media with NBR Seal:

Media with Viton Seal:

14°F to 176°F (-10°C to 80°C)

5°F to 248°F (-15°C to 120°C)

Operating Pressure Vacuum to 200 PSI Vacuum to 150 PSI
Electrical Connection
Standard Options:

Upgrade Options:

DIN 43650A

Grommet

Explosion Proof Coil (200C-E)

ATEX Explosion Proof Coil (200C-ATEX)

Coil Power 3W to 6.5W
Voltage Options
12VDC

24VDC

24VAC (50/60Hz)

110/120VAC (50/60Hz)

220/240VAC (50/60Hz)

Voltage Tolerance ±10% of Specified Voltage
Ingress Protection IP65
Insulation Class H Class
Coil Duty 100% ED, Continuous Duty
Installation No Orientation Requirement

Optimum Position: Flow Horizontal and Solenoid Vertical

Service Liquid, Water, Oil, Air

 

Dimensions

2S012-020-A Series Solenoid Valve Dimensions
Model Port A B C D E
2S012-1/8A 1/8″ NPT 62.7 66.6 31.5 20 48.7
2S012-1/4A 1/4″ NPT 62.7 66.6 34.5 25 48.7
2S020-1/8A 1/8″ NPT 62.7 66.6 31.5 20 48.7
2S020-1/4A 1/4″ NPT 62.7 66.6 34.5 25 48.7
Dimensions for Reference Use Only: Units in mm

To Connect the Valve Inlet & Outlet:

Connect the inlet & outlet to the valve ports according to the flow direction arrow marked on the valve

To Install the Coil:

Put the coils on to the armature tube of the valve. Place the lock washer & nut on to the armature tube. Hand tighten the nut, then use a wrench to tighten the nut another quarter-turn. Do not over-tighten the nut, as it may cause the armature tube to fail prematurely.

To Connect a DIN Coil:

1. Remove the Philips-head screw from the plastic DIN housing & unplug it from the DIN coil

2. From the screw opening, push the terminal block out from the plastic DIN housing.

3. Note the “1”, “2”, and ground “⏚” symbols on the underside of the DIN enclosure.

4. For DC DIN Coils, connect “1” to your Positive Lead & “2” to your Negative lead.

5. For AC DIN Coils, connect “1” to your HOT lead, “2” to your Neutral lead, & “⏚” to your ground if required.

Do not energize the coil without installing it onto the valve or connect the coil to a different voltage than specified. This will burn the coil and could create fire hazards.

Safety Note: Standard valves are supplied with continuous duty coils. The proper class of insulation for the service is indicated on the coil body. The coil temperature may rise significantly if energized for extended periods—this is normal. Although the coil is made of flame-retardant material, misuse of the coil could create fire hazards & generate smoke and/or a burning odor. If these conditions are encountered, the coil temperature has risen above safe levels and the power should be disconnected immediately.

Operation: This valve is a two-way, normally closed, direct-acting valve & does not require a minimum differential pressure to operate. As shown in the diagrams below, when the coil is de-energized (left diagram), the plunger rests on the main orifice & is held in place by the plunger spring force, sealing the valve. When the coil is energized (right diagram), the solenoid lifts the plunger & allows the working medium to flow through the orifice. The working medium & flow direction are indicated in purple in the diagrams.

 

Operation Diagram

Flow Rate

Additional information

Part No.

2S012-1/8A, 2S012-1/4A, 2S020-1/8A, 2S020-1/4A

Reviews

There are no reviews yet.

Be the first to review “Solenoid Valve Specifications and Dimensions: 2S012-020-A Series”

Your email address will not be published. Required fields are marked *